At Shiva Energy, we have been working with various Solar Installers and contractors for over a decade, providing them end-to-end solution for Solar PV design services requirements. We have in-depth knowledge of state/AHJ requirements and have been maintaining a high first-time approval rate. The various touchpoints/contributions of Shiva Energy includes:
Creation of proposal drawings including financial analysis,
Creation of Residential Solar Permit Plan set for PTI (Permission to Install)/Interconnection approval,
Engineering reviews by Professional Engineers
As-Built drawings to procure PTO (Permission to Operate)
Teams at Shiva Energy have extensive experience and knowledge in designing Residential Solar Permit Plans. We work with our customers to provide end-to-end solution for their residential PV plan requirements starting right from Proposal creation to Permit Set creation, Engineering Review and As-Built creation.
Proposal Drawing are one of the initiations point and are very critical. We have large teams who have extensive knowledge of various industry standards and guidelines used by various States/AHJs and are capable of turning around the proposals at a very fast pace. We are platform agnostic and are open and swift to adapt any existing workflows which may be interacting with your sales teams.
For large proposal requirements, we even setup dedicated workforce who work in sync with your sales team and provide almost real-time support while you are out selling. Typical turnaround times for proposals are 12 Hrs.
Our teams are experienced with creating Proposal Drawings with most optimum solar production proposals with just having an address and any specific client requirements.
Residential Solar Permit Plan Sets or Construction drawings are another critical component of the process. We understand and ensure that the permit sets created are precise, accurate, complete and clean/aesthetically pleasing for the installation team to understand and install solar panels in the field as per plan.
Our teams are well aware of National Electric Codes (NEC) and other applicable codes for various AHJs and Home Owner Association (HOA) requirements. We are pretty swift in adapting codes changes and any custom requirements from customer, installer and/or EPCs.
Designers at Shiva Energy are well conversant and acquainted with requirements and design specifications for different type of installations and Interconnections:
Flush Mounts installation
Tilt Roof Mount
Non-Penetrating Roof Mount
Ballast
Ground Mount Installations
Microinverters
On-Grid / Off-Grid
Hybrid
Battery Backups
While we are open to adapt to customer templates and design specification to ensure that you and your team do not see a change in their ongoing process, we have our own comprehensive templates as well. These templates are customized to use blocks and data tables to ensure consistency and accuracy in data and design.
Our typical Residential Solar Permit Plan Set includes the following; however, these are customizable and adaptable to any specific need:
Title Page
Sheet index
Governing Codes section
Vicinity map, parcel map, aerial view
Description of the project
PV Layout
Locations of all major components and equipment
Attachment point spacing
Point loads
Conduit runs
Solar PV array location and dimensions
Mounting Method
Elevation of attachment method
Racking and mounting hardware
Structural sections
Wiring Diagram
3-line wire diagram
Wire and conduit sizing
String / Branch circuit sizing for DC and AC systems
Grounding details
Interconnection method (breaker, line-side splice, subpanels, etc.)
All electrical calculations
System specifications
Signage
All required placards
Specifications of placard physical sizes
Specification Sheets
Solar Modules
Inverters
Racking
Typical inputs required for completion of a permit plan are home owner details, equipment details including module, inverter, racking system and attachment details, an approved layout or any guidelines on required system size, structural details, photos along with site measurements of roof (in case site measurements are not available, these are designed based on google/nearmap images, as may be available) and details and photos of existing electrical equipment and locations.
Availability of the above information ensures accurate and efficient system design in the first-go and early AHJ acceptances.
While the permit set design is done to best of available information including measurements and obstruction locations, sometime however, variations are observed in field and the installation team has to deviate/accommodate the actual field situation. This at times result in change of layout, interconnection used or other parameters.
As_Builts are generally required for the record of Home owners to keep a copy of the final installation plan and at times required by AHJs before proving Permit to Operate (PTO).
We would only require the change information, may be marked on the initial plan or a sketch of changes to make the As-Builts and deliver them on priority.
Revisions/Changes
We at Shiva Energy do acknowledge the fact that there are instances when the created Plan set require changes and address such change/revision requests on priority and ensure that the required changes with complete impact analysis are implemented in the first go itself and thus maintaining the overall turn-around time. The changes may occur due to change in racking system, mounting plans or layout, electrical equipment or any specific requirement from AHJ and our teams are able to handle all very swiftly.
Shiva Energy is a national leader in Solar Design Industry. We have delivered hundreds of structural Certifications and designs for Residential and Commercial solar installers that enables solar installers to get building permits.
We can facilitate Structural & Electrical Review & Stamps thru our licensed PE partners in ALL 50 STATES.
Whether you need structural certifications for one or a hundred jobs, Shiva Energy can assist you to prepare Certification Letters in a single business day. Our professional staff, combined with our proven proprietary systems, enables us to deliver affordable, high-volume, rapid, top-quality engineering services.
Send us your site audit form. We’ll perform professional engineering services, which generally take the form of a Structural Certification Letter, but can include custom engineering designs as well.
We offer our services in:
Evaluating structural loads
Solar panel placement
Structural reinforcement
Engineer's stamped drawings or letters for building departments
Structural certifications for building departments
Electrical P.E. Stamps (wet or digital)
Structural P.E. Stamps (wet or digital)